
name
Denisenko Evgeny Aleksandrovich
Scholastic degree
—
Academic rank
—
Honorary rank
—
Organization, job position
• Kuban State Agrarian University
ассистент
Research interests
Web site url
—
—
Current rating (overall rating of articles)
0
TOP5 co-authors
Articles count: 9
Сформировать список работ, опубликованных в Научном журнале КубГАУ
-
INFLUENCE OF RADIANT ENERGY ON THE WORK OF THE ELECTRO-OZONIZER MADE FOR STERILIZING SUBSTRATES
Description
The thermal balance of an electro-ozonizer is presented in this article. As the share of radiant energy having impact on heating of the generator of ozone is defined and the way of decrease in this influence is offered
-
INFLUENCE OF OZON-AIR MIX ON THE HARMFUL MICROORGANISMS CONTAINING IN SUBSTRATA
Description
Article is devoted to justification of influence of ozon-air mix at sterilization of vegetable substrata and fodder grain in the course of biotechnological production
-
SOURCES OF UNINTERRUPTED AND AUTONOMOUS POWER SUPPLY
Description
The article describes the main block diagrams of three types of uninterruptible power supply: backup; interactive; double conversion. The main functions are: the function backup or emergency source of electrical power; the function of protective devices (from an overload currents and short-circuit); improving the quality of the power supply voltage. Alsoб we have disclosed the features of the advantages and disadvantages of uninterruptible power supplies three groups: Off-Line / Stand-By / back-up UPS (passive - reserve); Line-Interactive (line interactive type); On-Line. The article discloses new approaches to structural and schematic-based uninterruptible power supply, including at use of renewable energy, so that the failure of one of the sources does not lead to exit from the operation of the entire of power supply system. As a rule, such systems are built on a modular principle. It is shown that now for remote users from external networks is advisable to apply a system autonomous power supply, representing the totality of sources and converters of electric power, ensuring uninterrupted power supply to consumers. We have presented a typical structure of autonomous systems and given an option of the block diagram of the system and are given explanations and principles of its work. Significantly improves performance reliability of autonomous systems using the modularity of its main functional units. In addition, to increase the efficiency of the system can be through the use in the construction of transformers with static converters rotating magnetic field. To improve the weight, which is important for the transport systems, it is necessary to use links with the intermediate high-frequency electric power conversion in static converters
-
CHOOSING SOLAR PHOTOVOLTAIC PLANT
Description
Promising is the direction and, above all, in matters of energy saving and energy efficiency of Autonomous systems of power supply, the use of renewable sources-newable energy as a major source of energy for consumers in remote areas. Here priority is given to solar energy. Since solar radiation can be change place not only in heat and electrical. The article contains three main structural schematics of electricity supply with solar power plants. The features of their work are disclosed, as well as an algorithm for calculating solar energy systems, the sequence of which is to define the required parameters, the daily energy consumption by consumers of electric power, the calculation capacity of the battery, the choice of the inverter and determining the area of solar batteries. The article reveals the conditions that affect the calculation of the PV system. It is shown that the greatest efficiency, including economic and reliability we have at combined (hybrid) Autonomous system, which was carried out with both solar power and wind power and gas stations. The important matters of improving the reliability of solar systems are the introduction to the design of a new element of the base, and first and foremost, Autonomous inventors performed on a single-phase transformer with a rotating magnetic field
-
TO THE CALCULATION OF THE ECONOMIC POTENTIAL OF WIND ENERGY AND THE CHOICE OF WIND POWER PLANTS
Description
To determine the feasibility of using PV systems we should assess the economic efficiency of wind energy in the region. At the same time, the first step should be an analysis of upper-air and power characteristics of the wind. The next stage is to determine the energy source of wind power (theoretical, technical and economic potential). The basic approach to the calculation of economic indicators should include a determination of the effectiveness of wind power installations in competition with traditional energy sources in a particular region. There are important following indicators: the payback period and economic efficiency. If the economic potential of wind power satisfies the requirements, the next step is to study the technical requirements applicable to wind power stations. For a preliminary assessment of the terrain, the article discloses a sequence of events that must be performed to assess the effectiveness of the installation of wind power systems. We have listed advantages and disadvantages of the main types of wind power plants, and other ramifications of choosing of basic functional units. The considered in an article analytical expressions for calculating the evaluation of economic efficiency of wind energy, the technical requirements for the basic parameters of wind turbines and their main advantages, disadvantages and features the work will allow at the design stage to carry out a preliminary assessment of effectiveness of the wind power stations for a particular region and locality, specific types consumers in view of their modes of operation and the quality requirements of electricity
-
Description
The article is devoted to the construction of nomograms for determining geometrical dimensions of electroisolator the amount of residual pathogenic microflora on the surface of plant substrates coreproducts
-
FREQUENCY CONVERTERS WITH IMPROVED PERFORMANCE
Description
In the autonomous power supply systems there are widely used frequency converters that are able to simultaneously increase or decrease the frequency of the current and voltage stabilizing power supply. These positive properties of frequency converters can improve the operational and technical characteristics of the autonomous power supply system in the complex. The article suggests a functional diagram of a frequency converter performed on reversible rectifiers. We have presented timing diagrams illustrating the principle of its operation. The article also deals with two functional scheme of direct frequency converters executed on single-phase, threephase transformer with a rotating magnetic field. The principle of operation of these schemes has been also discussed in the timing diagrams. The proposed technical solutions for frequency converters contain a smaller amount of power electronic devices that make it possible, thereby reducing the level of electromagnetic interference, increase the efficiency and reliability of performance inverters. The considered scheme of frequency converters, can improve the technical characteristics of the autonomous power supply systems in the complex. We can significantly improve the performance of power systems through the use of modular aggregating principle of the basic functional units of an autonomous system
-
SYNTHESIS OF MODULAR UNINTERRUPTED POWER SUPPLY SYSTEMS WITH INCREASED RELIABILITY
Description
The level of technical development today requires the creation of highly effective, including reliable, uninter-rupted power supply systems. We have shown modern requirements and design features of modern systems of uninterruptible power supply, which should be built on a modular principle. It is shown that the problem of synthesis of systems in a modular approach is addressing three issues: development of the structure of the system subject to the requirements of consumers to quality of power and the allowable time of power outage; determining the required level redundancy of major functional units (blocks, elements) to ensure the required reliability of the system; - ensuring the most effective interconnection of modules, including electromagnetic compatibility, and the rational use during normal and emergency operation of the system. We have proposed new structural solution of the main functional units and uninterrupted power supply systems in modular design. To reduce EMI and improve efficiency uninterruptible power supply systems in the design of static converters we need to use a transformer with a rotating magnetic field. In addition, the prospective current is to be used as a source of renewable energy. Another promising approach is the use of direct frequency converters as voltage stabilizers and frequency of the current
-
FEASIBILITY STUDY ON USE OF OZONE FOR DISINFECTION OF VEGETABLE SUBSTRATA
Description
The study of the use of ozon-air mix is presented in the article as a disinfecting substance in production of dietary supplement. A comparative analysis of various technologies of sterilization is provided